© Kontraframe
PROJECT INFO
Building type:
办公建筑
Year:
2011
Project Status:
已建
Gross Area:
4000 Sqm
Certificates:
Climatic zone:
大陆性气候
MY LAST SEEN PROJECTS
PROJECT DESCRIPTION
The new office building of Energinet.dk in Ballerup is a low-energy building. The lowest energy class possible has been achieved exclusively by means of optimizing the design and geometry.
The building has an annual energy consumption of only 47,7 kWh/m2. Incorporating solar panels, ground water cooling and heat pumps in the project would further reduce the annual energy consumption to only 35 kWh/m2.
The new office building of Energinet.dk covers 4,000 m2. The simple architectural design has resulted in a flexible and easily comprehensible building consisting of three elements: meeting facilities on the ground floor, a uniting atrium and workstations on the top floor, which floats above the sloping landscape. The atrium is identity-creating, open and active.
A significant part of the environmental objective has been to ensure a high degree of flexibility. The open layout of the first floor as well as the light walls and simple, reusable elements will make it easy and problem-free to change the interior layout in the future.
AWARDS
SUSTAINABILITY FEATURES
被动式设计/太阳能
高效外墙
太阳能水暖
可持续建材
低挥发性有机化合物材料
智能设计 (被动式设计策略)
现场可再生能源
地源热泵
绿化屋顶
日光最大化
户外视野最大化
SUSTAINABILITY STRATEGY
The design of the new office building of Energinet.dk has been based on three overall environmental objectives:
• Local disposal of rainwater (LAR) resulting in a reduced load on the sewage system and reduced water consumption.
• Making use exclusively of materials that ensure a good indoor climate, small environmental impact and a minimum of maintenance.
• Low energy consumption and reduction of CO2 emissions.
Henning Larsen Architects has designed a low-energy building solely by means of optimizing the design and an geometry - resulting in an office building in the lowest energy class possible. The building has an energy consumption of only 47,7 kWh/m2 a year. Incorporating solar panels, ground water cooling and heat pumps in the project would further reduce the annual energy consumption to only 35 kWh/m2. The building meets the requirements for low-energy class 1 according to Danish building regulations without the use of energy producing technologies.
The design is based on the integrated energy design concept where the building is designed to achieve the lowest energy class possible - and thus the lowest possible maintenance and operation costs.
In order to reduce the energy consumption of the building, the design team has focused on:
Shape and orientation:. A compact building (large volume compared to surface area) reduces the heat loss and use of materials.
Functional positioning:. The energy consumption can be reduced significantly by means of a proper positioning of the various functions of the building. Permanent workstations are placed to the north-west and north-east to avoid overheating and blinding.
Daylight optimization:. By testing different daylight scenarios, the use of light and heat from the sun is optimised and the use of artificial lighting is reduced. Tailoring the light to the specific needs further optimises the use of artificial lighting. In the design process, light simulations have been applied to optimise the design and reduce the energy consumption for artificial lighting and cooling.
In the design process, a comfortable inflow of daylight has been ensured by means of the following:
• Permanent sunlight protection on the facades to avoid a direct inflow of daylight and overheating.
• Indirect inflow of daylight from overhead lights in the atrium.
• Direct sunlight from the west in summer in the cafeteria and conference rooms. During the rest of the year, the rooms are in shadow.
The offices feature three-layer low-energy windows and, in some places, north-facing overhead lights. The offices only have direct sun from the west in summer. For the rest of the year, the rooms are in shadow.
The building has a green roof serving several sustainable purposes: It reduces the load on the public sewage system by means of slow percolation and evaporation. In addition, the collected rainwater is used for flushing the toilets and watering the garden, which contributes to reducing the overall energy consumption for cooling.
ENERGY DATA
Energy consumption:
35.00 KW/m² (11.095 KBtu/ft²)
Consumption type:
真实数据
Annual carbon footprint:
N/A (N/A )
Climate zone:
大陆性气候
Min. temperature =
-2
Max temperature =
+22
RH =
N/A
CLIENT
Client:
Energinet.dk
DESIGNERS
Architect:
建筑师:
Henning Larsen Architects
CONSULTANTS
建筑服务工程师:
Hansen, Carlsen & Frølund Consulting Engineers
结构工程师:
Hansen, Carlsen & Frølund Consulting Engineers
能源顾问:
Hansen, Carlsen & Frølund Consulting Engineers
专业顾问:
Schul Landscape Architects
CONTRACTORS
总承包商:
Dahl Entreprise A/S
OTHER PROJECTS BY TEAM
SIMILAR PROJECTS
Avenida República do Chile - Centro, Rio - Rio de Janeiro, Brazil | 2013
Via Filippo Turati, 25, 20121 Milano, Italia | 2012
Via Energy Park, 20871 Torri Bianche MB, Italy | 2009
Seattle, WA, USA | 2012
Via Umberto Forti, 1, 56121 Montacchiello PI, Italia | 2016
Via Chiese, 72, 20126 Milano MI, Italia | 2018
Viale della Liberazione, 20124 Milano MI, Italia | 2017
Via Bernina, 12, 20159 Milano MI, Italia | 2012
New Cairo City, Cairo Governorate, Egypt | 2016
Parma, Province of Parma, Italy | 2018
Manhattan, New York, NY, USA | 2016
Via Fabio Filzi, 29, 20124 Milano MI, Italia | 2015
Piazza Tommaso Edison, 20123 Milano MI, Italia | 2017